Skip to main content
. Author manuscript; available in PMC: 2020 Feb 1.
Published in final edited form as: IEEE Trans Med Imaging. 2018 Aug 13;38(2):394–405. doi: 10.1109/TMI.2018.2865356

TABLE IV.

Five-fold cross-validation results. The PSNR values are shown for 6X and 10X acceleration factors in the format: mean ± std, min / max. Column 1 represents the ith testing subject as Sub i.

Testing on 6 fold acceleration 10 fold acceleration
Sub 1 39.57±1.55, 36.40/43.79 37.95±1.68, 34.30/42.48
Sub 2 39.56±1.23, 35.13/43.85 37.57±1.26, 34.92/42.71
Sub 3 39.19±0.98, 36.46/43.03 37.38±1.15, 33.58/41.44
Sub 4 37.73±1.15, 34.07/41.11 36.27±1.13, 33.24/39.66
Sub 5 39.35±1.27, 35.33/42.59 37.59±1.16, 33.77/40.73
Avg. 39.08±1.23, 35.47/42.87 37.35±1.27, 33.96/41.40