Skip to main content
. 2019 Sep 24;57(10):e00274-19. doi: 10.1128/JCM.00274-19

TABLE 2.

Sensitivity and specificity of cytokine tests estimated by ROC analysisa

Effect Diagnostic antigen Area under ROC curve Sensitivity (%) 95% CI (%) for sensitivity Specificity (%) 95% CI (%) for specificity Cutoff value (ng/ml)
Differentiate M. bovis-infected cattle from NC PPD-B-stimulated IL-8 0.9662 92.86 80.52–98.50 94.74 73.97–99.87 >32.57
92.86 80.52–98.50 100 82.35–100.0 >43.05
CE-stimulated IL-8 0.9561 85.71 71.46–94.57 94.74 73.97–99.87 >21.9
85.71 71.46–94.57 100.0 82.35–100.0 >29.42
PPD-B-stimulated IP-10 0.9500 52.38 36.42–68.00 95 75.13–99.87 >1.992
52.38 36.42–68.00 100 83.16–100.0 >2.045
PPD-B-stimulated IL-17A 0.8464 28.57 15.72–44.58 95 75.13–99.87 >1.767
28.57 15.72–44.58 100 83.16–100.0 >2.061
Differentiate bTBPCR-P and bTBPCR-N PPD-B-stimulated CRP 1.000 100 83.89–100.0 95.24 76.18–99.88 >701.3
100 83.89–100.0 100 83.89–100.0 >794.8
Unstimulated IL-8 0.8322 52.38 29.78–74.29 100.0 83.89–100.0 <4.088
52.38 29.78–74.29 95.24 76.18–99.88 <4.648
PPD-B-stimulated AGP 0.7732 52.38 29.78–74.29 95.24 76.18–99.88 <49,925
42.86 21.82–65.98 100.0 83.89–100.0 <46,732
Serum SAA 0.7914 38.10 18.11–61.56 95.24 76.18–99.88 >12,082
38.10 18.11–61.56 100.0 83.89–100.0 >12,495
a

The cutoff values for the PPD-B-stimulated IL-8, IP-10, and IL-17A ELISAs were obtained using 19 healthy cattle and 42 M. bovis-infected cattle. The cutoff values for the PPD-B-stimulated CRP, PPD-B-stimulated AGP, unstimulated IL-8, and serum SAA ELISAs were obtained using 21 bTBPCR-P and 21 bTBPCR-N. CI, confidence interval. The PPD-B-stimulated IL-8 ELISA showed a higher area under the ROC curve (AUC = 0.9662) and was better than the CE-stimulated IL-8, PPD-B-stimulated IP-10, and IL-17A ELISAs at differentiating M. bovis-infected cattle from NC. The PPD-B-stimulated CRP ELISA was better than the unstimulated IL-8, PPD-B-stimulated AGP, and serum SAA ELISAs at differentiating bTBPCR-P and bTBPCR-N. The specificity for each diagnostic antigen was set at nearly 95% or 100%, and the sensitivity, area under the ROC curve, and cutoff value were calculated and are shown.