Skip to main content
. 2019 Sep 6;6(9):1807–1814. doi: 10.1002/acn3.50885

Figure 1.

Figure 1

Gross anatomic deformations. Two patients, one with midline cysts (left) and another with ex vacuo ventricular dilation (right), were included in the study to assess the robustness of the automated algorithms to gross anatomic deformations distant from the hippocampus. Both automated segmentation algorithms failed on these two cases.