Skip to main content
. 2019 Sep 15;2019:6834931. doi: 10.1155/2019/6834931

Table 2.

Mean and standard deviation of the release of fluoride ions from the materials tested in the evaluation periods of 1, 2, 5, 10, and 15 days.

Materials Mean and standard deviations of fluoride release (μg/cm2) Cumulative fluoride
Day 1 Day 2 Day 5 Day 10 Day 15
Fuji II 33.9 ± 3.7Ab 11.2 ± 0.8Bc 4.6 ± 0.2Cb 2.4 ± 0.5Db 0.8 ± 0.4Db 85.4 ± 8.6
Fuji II Caps 47.3 ± 5.0Aa 15.7 ± 2.7Ba 6.1 ± 1.3Cab 3.6 ± 1.2Dab 1.4 ± 1.0Eb 118.3 ± 11.9
Fuji II LC 28.9 ± 0.7Ac 14.2 ± 1.7Bab 6.8 ± 0.2Ca 4.2 ± 0.4Dab 3.1 ± 0.2Da 113.8 ± 3.9
Fuji II LC Caps 28.8 ± 0.9Ac 13.3 ± 0.1Bb 7.1 ± 0.3Ca 5.2 ± 0.3Da 4.2 ± 0.09Da 119.7 ± 2.0
Ionoseal 0.1 ± 0.1Ad 0 ± 0Ad 0 ± 0Ad 0 ± 0Ac 0 ± 0Ac 0.1 ± 0.1

Different capital letters mean statistical significance within line (p < 0.05). Different lowercase letters mean statistical significance within columns (p < 0.05).