Skip to main content
. 2019 Sep 16;12(18):2998. doi: 10.3390/ma12182998

Table 1.

Comparison of parameters by cone calorimeter test: time to ignition, tig, HRR results, and total heat release (THR) for measurements performed at irradiance 35 kW/m2.

Samples tig
(s)
tHRRpeak
(s)
pHRR
(kW/m2)
pHRR
Delta %
HRR
Average
(kW/m2)
HRR
Average
Delta %
THR
MJ/m2
THR
Delta %
RTM6 panel 91 124 301 118 20
Nanofilled panel 120 147.5 236.5 −21.43 60.7 −48.56 17 −15.00