Skip to main content
. 2019 May 17;82(4):1301–1311. doi: 10.1002/mrm.27805

Table 1.

Signal‐to‐noise ratio, lung ventilated volume, and ventilation percentage defect measurements calculated from fully‐sampled and retrospectively accelerated scan datasets from eight healthy volunteer participants

Participant Fully sampled Retrospectively accelerated
SNR VV / L VDP / % SNR VV / L VDP / %
A 13.5 4.67 0.6 13.8 4.49 1.1
B 5.8 4.70 1.5 6.4 4.35 1.5
C 15.9 5.65 0.5 17.0 5.47 2.7
D 8.6 7.76 2.1 7.9 7.26 3.7
E 7.9 4.36 2.4 8.9 3.92 2.6
F 7.6 6.33 1.7 9.1 5.89 1.7
G 14.3 3.82 2.9 14.4 3.48 2.3
H 13.1 6.27 0.4 12.5 6.07 0.7
Mean 10.8 5.45 1.5 11.3 5.12 2.0

Abbreviations: SNR, signal‐to‐noise ratio; VDP, ventilation defect percentage; VV, lung ventilated volume.