Table 3.

Temperature differences for three different sets of values of ΔM and P/k for the 60CoCo thermometer. All the temperatures were calculated using the values of W(0) shown. The latter were chosen to give values of T for ΔM = −6.0725 mK and P/k = −2.2 μK which cover the thermometers useful temperature range (1.3-50 mK). The values used for U2A2 and UλAλ are those given in table 1 for the 1332.5 keV transition. Solid angle correction factors were Q2 = 0.9965 and Q4 = 0.9886. See text for further details.

W(0) T T′ (T′−T)/T T′ (T′−T)/T
ΔM = −6.0725 mK ΔM = −6.0653 mK ΔM = −6.0668 mK
P/k = −2.2 μK P/k = −2.5 μK P/k = −2.9 μK
0.014932 1.30000 mK 1.29904 mK −0.074% 1.30012 mK +0.010%
0.327535 5.00000 4.99606 −0.079 4.99993 −0.001
0.470108 6.90000 6.89437 −0.082 6.89945 −0.008
0.633327 10.00000 9.99147 −0.085 9.99835 −0.016
0.783152 15.00000 14.98679 −0.088 14.99656 −0.023
0.860948 20.00000 19.98236 −0.088 19.99537 −0.023
0.931038 30.00000 29.97466 −0.084 29.99561 −0.015
0.959508 40.00000 39.96856 −0.079 39.99951 −0.001
0.973528 50.00000 49.96406 −0.072 50.00723 +0.014