Skip to main content
. 1983 May-Jun;88(3):175–217. doi: 10.6028/jres.088.011

Table 8.

Temperature errors due to the mosaic spread for the 60CoCo(hcp) thermometer. Calculations were done for mosaic spreads (FWHM) of 1° and 2°. The distribution of local c-axes was assumed to be Gaussian. The same parameters were used to determine W(0) and T as those used in table 3. See text for further details.

W(0) T ΔT/T ΔT/T
FWHM = 1° FWHM = 2°
0.014932 1.3 mK 0.305% 1.210%
0.327535 5.0 0.018 0.073
0.470108 6.9 0.013 0.050
0.633327 10.0 0.009 0.034
0.783152 15.0 0.006 0.025
0.860948 20.0 0.005 0.021
0.931038 30.0 0.005 0.018
0.959508 40.0 0.004 0.018
0.973528 50.0 0.004 0.017