Muth 1996.
Methods | Single‐centre study in Germany | |
Participants | 50 patients of average age 65 years undergoing elective repair of abdominal aortic aneurysm Inclusion/exclusion criteria were not described |
|
Interventions | No warmed intravenous fluids (n = 25): total volume fluid replacement 3449 ± 1380 mL, surgical duration 173 ± 8 minutes Intravenous fluids warmed via countercurrent‐like heat exchangers (hotline) (n = 25): total volume fluid replacement 3499 ± 1623 mL, surgical duration 171 ± 59 minutes |
|
Outcomes | Oesophageal temperature at end of surgery | |
Notes | ||
Risk of bias | ||
Bias | Authors' judgement | Support for judgement |
Random sequence generation (selection bias) | Low risk | 'Random allocation according to patients' day of surgery (odd or even numbers)' |
Allocation concealment (selection bias) | Unclear risk | Not described |
Blinding of participants and personnel (performance bias) All outcomes | Unclear risk | Not described |
Blinding of outcome assessment (detection bias) All outcomes | Unclear risk | Not described |
Incomplete outcome data (attrition bias) All outcomes | Low risk | No loss to follow‐up |
Selective reporting (reporting bias) | Low risk | No evidence of this |
Other bias | Low risk | None |