Skip to main content
. 2019 Aug 28;9(3):103. doi: 10.3390/bios9030103

Table 1.

Diameter measurement and conductivity of fibers spun from PEDOT:PSS aqueous solution (2.5%, 5%, 10%) using different gauge needles (21 G, 27 G, 32 G with nominal inner diameters of 514 µm, 210 µm, and 108 µm, respectively). The average values from three different fibers are reported.

PEDOT:PSS
Concentration
Gauge Avg. Diameter
(μm)
Im/Vf
(A/V)
Conductivity
(S/cm)
2.5% 32 G 22.34 2.21 × 10−4 214
27 G 23.60 2. 49 × 10−4 216
21 G 38.36 6.87 × 10−4 226
5% 32G 11.53 2.49 × 10−4 716
27G 18.82 4.48 × 10−4 483
21G 29.79 1.02 × 10−3 439
10% 27G 49.10 7.13 × 10−4 144