Author Test Aging Storage Highest Value/Lowest Value (MPa)
Saulo Pamato Microshear bond strength ______________ _____________ Adper Single Bond 2: 16<break/>U 200: 11.190
Pekperdahci Microshear bond strength Water 5 °C/55 °C for 10,000 cycles Distilled water at 37 °C for two days ARC Single Bond 2: 370.07
Relyx Unicem/Adper Prompt 77.06
Chávez Microshear bond strength _____________ Distilled water and kept at a constant temperature of 37 °C Relyx ARC Single Bond 2: 15.52
Set PP 3.17
Ozturk Microshear bond strength Thermocycled between 5 °C and 55 °C in Deionized water for 5000 cycles. Distilled water for 24 h at 37 °C Variolink Venner/Heliobond: 24.76 (enamel)
RelyX Veneer/Adper Scottchbond: 5.42 (dentin)
Lorenzoni Microshear bond strength ______________ ________________ Adper Single Bond 2/Duo
Link: 14.5
All Bondl/Duo
Link: 6.16
Aguiar Microtensile bond strength Mechanical load cycling, submitted to 50,000 cycles Artificial saliva for 1 day Relyx Unicem: 21.3
Clearfil Esthetic Cement/Clearfil DC Bond: 13.3
Vaz Microtensile bond strength ______________ 37 °C and 100% relative humidity Relyx ARC/Adper Single Bond 2: 40.8
C&B Cement/All-Bond 2: 19.5
Bacchi Microtensile bond strength Pulpal pressure for 3 months 20 cm distilled water Relyx ARC/Adper single bond 2: 25
U200: 8
Alexandre Microtensile bond strength Pulpal pressure for 24 h Distilled water Clearfil SE Bond/Panavia F: 38.0
Panavia 21/Panavia F2.0: 7.8
Roperto Microtensile bond strength _______________ Water for 24 h at 37 °C Primer and Bond NT/Calibra: 17.68
Smart Cem: 6.48
Skupien Microtensile bond strength Distilled water at 37 °C for 24 h Adper Scotchbond/Relyx ARC: 20.29
U100: 9.69