Skip to main content
. 2018 Apr 4;557(7703):71–75. doi: 10.1038/s41586-018-0017-2

Table 3.

Summary of uncertainties

Type of uncertainty Estimated size (kHz) Comment
Statistical uncertainties 3.8 Poisson errors and curve fitting to measured data
Modelling uncertainties 3 Fitting of simulated data to piecewise-analytic function
Modelling uncertainties 1 Waist size of the laser, antihydrogen dynamics
Magnetic-field stability 0.03 From microwave removal of 1Sc-state atoms (see text)
Absolute magnetic-field measurement 0.6 From electron cyclotron resonance
Laser-frequency stability 2 Limited by GPS clock
d.c. Stark shift 0.15 Not included in simulation
Second-order Doppler shift 0.08 Not included in simulation
Discrete frequency choice of measured points 0.36 Determined from fitting sets of pseudo-data
Total 5.4