Table 5.

Comparisons of the diagnoses of the ectopic parathyroid glands.

Imaging modality TP TN FP FN Accuracy Comparison of accuracy: P value, sign test with Bonferroni correction
vs. CT vs. US vs. MIBI vs. CT and US vs. CT and MIBI vs. US and MIBI
CT 43 0 0 47 0.478 ref
US 33 0 0 57 0.367 0.999 ref
MIBI 27 0 0 63 0.300 0.210 0.999 ref
CT and US 54 0 0 36 0.600 0.021 <0.001 <0.001 ref
CT and MIBI 52 0 0 38 0.578 0.084 0.021 <0.001 0.999 ref
US and MIBI 44 0 0 46 0.489 0.999 0.021 <0.001 0.441 0.999 ref
CT, US, and MIBI 57 0 0 33 0.633 <0.001 <0.001 <0.001 0.999 0.999 <0.001

TP, True positive; TN, True negative; FP, False positive; FN, False negative; ref, reference; CT, computed tomography; US, ultrasonography; MIBI, Tc—99m sestamibi scan.

Bold face font denotes statistically significant P-values.