Skip to main content
. 2019 Oct 10;6:149. doi: 10.3389/fcvm.2019.00149

Table 6.

Inter-observer reproducibility based on re-reading the good quality scans (N = 10).

Mean (95% CI) Bias ICC
1st observer 2nd observer Mean Δ ± SEM (95% CI)
SDI volume, % 5.1 (4.3, 5.8) 5.1 (4.3, 5.9) 0.05 ± 0.08 (−0.11, 0.21) 0.96
CS-SDI, % 5.0 (4.0, 5.9) 6.1 (4.5, 7.7) 1.1 ± 0.37 (0.40, 1.9) 0.77
LS-SDI, % 1.9 (1.7, 2.3) 1.9 (1.5, 2.3) −0.10 ± 0.16 (−0.41, 0.21) 0.50
PTS-SDI, % 4.0 (3.4, 4.7) 4.4 (3.2, 5.6) 0.34 ± 0.35 (−0.33, 1.0) 0.64
RS-SDI, % 3.8 (3.0, 4.6) 3.7 (2.8, 4.6) −0.08 ± 0.23 (−0.53, 0.37) 0.79
Di volumes, % 15.3 (13.8, 16.8) 15.4 (13.6, 17.1) 0.05 ± 0.36 (−0.66, 0.76) 0.86
CS-Di, % 16.6 (13.4, 19.8) 21.8 (15.6, 27.9) 5.1 ± 1.9 (1.3, 8.9) 0.55
LS-Di, % 7.1 (5.9, 8.2) 6.9 (5.4, 8.3) −0.23 ± 0.75 (−1.7, 1.2) <0.1
PTS-Di, % 13.6 (11.8, 15.3) 16.0 (10.6, 21.5) 2.5 ± 2.1 (−1.6, 6.6) 0.22
RS-Di, % 12.9 (10.9, 14.9) 13.3 (10.3, 16.2) 0.34 ± 0.83 (−1.3, 1.9) 0.69

Data are means (95% confidence intervals). Abbreviations as in Table 1.