Skip to main content
. 2019 Oct 17;8(5):27. doi: 10.1167/tvst.8.5.27

Table 3.

Results of Multivariable Regression Analysis for Prediction of IPL Thickness in 99 Glaucoma Eyes and 66 Healthy Eyes at Superpixels Level as a Function of Eccentricity From the Fovea


1.5° Eccentricity (Circle 1)
4.5° Eccentricity (Circle 2)
Coefficient (95%CI)
P Value
Coefficient (95%CI)
P Value
Age –0.261 (−0.059, 0.006) 0.121 −0.035 (−0.071, 0.001) 0.059
Race (ref: non-Asian) –0.849 (−1.583, −0.114) 0.024 −0.792 (−1.884, 0.299) 0.154
Axial length, mm 0.016 (−0.199, 0.231) 0.883 −0.049 (–0.312, 0.212) 0.708
GCL thickness, μm 0.900 (−0.010, 0.190) 0.077 0.161 (0.009, 0.314) 0.038
Glaucoma diagnosis –18.033 (−21.853, −14.215) <0.001 –17.623 (−25.030, −10.216) <0.001
Glaucoma diagnosis * GCL thickness 0.483 (0.381, 0.586) <0.001 0.352 (0.197, 0.507) <0.001