Skip to main content
. 2019 Oct 17;13:2043–2052. doi: 10.2147/OPTH.S202054

Table 3.

Visual And Refractive Outcomes At 3 Years Follow-Up

Patient Pre-UDVA (logMAR) Pre-BDVA (logMAR) Preoperative Refraction (D) Type Of Toric Phakic IOL Implanted 3 Years Post-UDVA (logMAR) 3 Years Post-BDVA (logMAR) 3 Years Postoperative Refraction (D)
1 1.30 0.20 −5.0–4.5×170° Artiflex 0.30 0.10 −0.75–2.50×100°
2 1.30 0.00 −13.0–2.0×150° Artisan 0.00 0.00 −0.50×170°
3 1.30 0.00 +2.5–6.5×10° Artisan 0.00 0.00 −0.50×20°
4 1.30 0.10 −6.0×30° Artisan 0.20 0.10 −1.00–2.00×110°
5 1.30 0.20 −7.5–10.0×145° Artisan 0.20 0.10 −2.00–2.00×55°
6 1.30 0.50 −8.0–10.0×90° Artisan 0.50 0.30 −1.00–1.00×70°
7 1.30 0.20 −4.0–5.0×55° Artiflex 0.20 0.00 −1.50×35°
8 1.30 0.20 −7.0–7.0×145° Artiflex 0.20 0.10 −1.25×110°
9 1.30 0.20 −1.0–8.5×50° Artisan 0.20 0.00 −1.00–0.50×40°
10 1.30 0.00 −5.5–11.0×10° Artisan 0.50 0.00 −3.00–0.75×0°
11 1.00 0.20 +3.0–11.0×105° Artisan 0.20 0.10 +1.00–2.50×100°