Table 3.
Visual And Refractive Outcomes At 3 Years Follow-Up
Patient | Pre-UDVA (logMAR) | Pre-BDVA (logMAR) | Preoperative Refraction (D) | Type Of Toric Phakic IOL Implanted | 3 Years Post-UDVA (logMAR) | 3 Years Post-BDVA (logMAR) | 3 Years Postoperative Refraction (D) |
---|---|---|---|---|---|---|---|
1 | 1.30 | 0.20 | −5.0–4.5×170° | Artiflex | 0.30 | 0.10 | −0.75–2.50×100° |
2 | 1.30 | 0.00 | −13.0–2.0×150° | Artisan | 0.00 | 0.00 | −0.50×170° |
3 | 1.30 | 0.00 | +2.5–6.5×10° | Artisan | 0.00 | 0.00 | −0.50×20° |
4 | 1.30 | 0.10 | −6.0×30° | Artisan | 0.20 | 0.10 | −1.00–2.00×110° |
5 | 1.30 | 0.20 | −7.5–10.0×145° | Artisan | 0.20 | 0.10 | −2.00–2.00×55° |
6 | 1.30 | 0.50 | −8.0–10.0×90° | Artisan | 0.50 | 0.30 | −1.00–1.00×70° |
7 | 1.30 | 0.20 | −4.0–5.0×55° | Artiflex | 0.20 | 0.00 | −1.50×35° |
8 | 1.30 | 0.20 | −7.0–7.0×145° | Artiflex | 0.20 | 0.10 | −1.25×110° |
9 | 1.30 | 0.20 | −1.0–8.5×50° | Artisan | 0.20 | 0.00 | −1.00–0.50×40° |
10 | 1.30 | 0.00 | −5.5–11.0×10° | Artisan | 0.50 | 0.00 | −3.00–0.75×0° |
11 | 1.00 | 0.20 | +3.0–11.0×105° | Artisan | 0.20 | 0.10 | +1.00–2.50×100° |