Skip to main content
. 2019 Jul 17;42(11):zsz165. doi: 10.1093/sleep/zsz165

Figure 2.

Figure 2.

Bidirectional case-crossover design used in this analysis. Each segment with an NSVT event was analyzed for hazard period (30 s preceding the onset of NSVT) and control periods selected from 2.5-min control windows spaced at 5-min intervals from the NSVT event. Three 2.5-min control windows with at least 1 30-s epoch of sleep is selected. If there is more than 1 epoch of sleep within the control window, 1 epoch of sleep is randomly selected to serve as the control period.