Table 9.
No. | Formulation | Ignition (Yes/No) | Time for Flame Tip to Reach 150 mm (s) | Extent of Flame Spread (mm) | Burning Droplets | Ignition of Filter Paper |
---|---|---|---|---|---|---|
1 | PLA/APP5/PES10/KL1 | No | Did not reach | None | No | No |
2 | PLA/APP5/PES10/KL3 | No | Did not reach | None | No | No |
3 | PLA/APP5/PES10/KL5 | No | Did not reach | None | No | No |