Ignitability test results of nonwoven fabric samples.

No. Formulation Ignition (Yes/No) Time for Flame Tip to Reach 150 mm (s) Extent of Flame Spread (mm) Burning Droplets Ignition of Filter Paper
1 PLA/APP5/PES10/KL1 No Did not reach None No No
2 PLA/APP5/PES10/KL3 No Did not reach None No No
3 PLA/APP5/PES10/KL5 No Did not reach None No No