Tool geometry used in experimental testing and the FE simulations.
Tool Parameters | Values |
---|---|
Corner radius | 1.191 mm |
Clearance angle | 6° |
Rake angle | −6° |
Tool lead angle | −17.5 |
Inclination angle | −7 |
Coating material | TiAlN |
Tool geometry used in experimental testing and the FE simulations.
Tool Parameters | Values |
---|---|
Corner radius | 1.191 mm |
Clearance angle | 6° |
Rake angle | −6° |
Tool lead angle | −17.5 |
Inclination angle | −7 |
Coating material | TiAlN |