Table 1.

Predicted absolute errors for clinical dose (%) for cases 10 (similar to the clinical dose distribution) and 11 (not similar to the clinical dose distribution)

DVH parameters % Error with clinical dose
Case 10 Case 11
PTV-1
D2% 0.38 0.87
D98% 1.92 2.03
PTV-2
D2% 0.01 0.74
D98% 1.00 0.93
PTV-3
D2% 2.27 0.71
D98% 0.23 5.18
Rectum
V35Gy 2.89 5.89
V50Gy 0.58 8.74
V65Gy 1.73 5.02
Bladder
V35Gy 0.72 13.30
V50Gy 1.24 9.97
V65Gy 1.68 4.62