Table 4.
Instrument | Technical Parameters |
---|---|
Leica NA3003 | Measuring distance: 1.3–100 m |
Precision of distance measurement: ± (3 mm + 5 pmm) | |
Accuracy per 1 km of double leveling: 0.4 mm (invar staff), 1.2 mm (standard staff) | |
Trimble VX | Maximum measuring distance: 250 m |
Precision of distance measurement: ± (1 mm + 2 pmm) | |
Angular accuracy 1″ | |
Z+F Imager 5010 | Maximum measuring distance: 187 m |
Beam divergence < mrad (full angle) | |
Beam diameter approx. 3.5 mm per 1 m | |
More than 1 million pixel/sec maximum measurement rate |