Skip to main content
. 2019 Sep 27;19(19):4205. doi: 10.3390/s19194205

Table A3.

Results of HR estimation, algorithm No. 1 (PSD)—comparison of signal extraction methods.

Video No. RMSE [bpm] sRate [%]
G GRD ExG ICA G GRD ExG ICA
video 1 10.7 4.5 3.2 7.8 48% 76% 85% 71%
video 2 16.5 15.2 15.7 14.7 27% 41% 39% 40%
video 3 16.5 13.9 12.9 2.8 47% 49% 57% 83%
video 4 10.1 11.6 7.3 3.2 45% 55% 65% 78%
video 5 3.9 2.2 2.5 2.8 84% 91% 91% 87%
video 6 14.1 13.5 11.1 7.2 43% 42% 65% 62%
video 7 3.5 3.7 3.4 2.2 80% 84% 86% 91%
video 8 6.8 17.9 17.2 4.0 61% 19% 25% 79%
video 9 22.2 36.7 35.8 34.8 11% 16% 15% 12%