Skip to main content
. 2019 Oct 18;24(6):568–575. doi: 10.1016/j.rpor.2019.09.014

Table 3.

Comparison between TPS measured and calculated (Fitted) isodose volumes and their percentage deviations from TPS and correlation coefficient for Ir-192 HDR brachytheray sources.

Ir-192 3 Gy
9 Gy
15 Gy
18 Gy
Plans TPS Fitted Fitted-TPS % Difference TPS Fitted Fitted-TPS % Difference TPS Fitted Fitted-TPS % Difference TPS Fitted Fitted-TPS % Difference
1 531.80 532.75 0.95 0.18 105.89 103.49 −2.40 −2.27 46.76 47.65 0.89 1.90 34.12 36.06 1.94 5.69
2 566.45 566.07 −0.38 −0.07 111.84 109.27 −2.57 −2.30 48.68 50.21 1.53 3.15 35.73 37.98 2.25 6.29
3 503.82 507.46 3.64 0.72 101.22 99.10 −2.12 −2.09 45.32 45.71 0.39 0.85 33.51 34.61 1.10 3.28
4 472.86 470.69 −2.17 −0.46 95.44 92.72 −2.72 −2.85 40.76 42.88 2.12 5.20 29.23 32.50 3.27 11.17
5 554.37 549.98 −4.39 −0.79 108.87 106.48 −2.39 −2.20 46.88 48.97 2.09 4.47 33.87 37.05 3.18 9.40
6 567.08 566.07 −1.01 −0.18 111.71 109.27 −2.44 −2.18 48.69 50.21 1.52 3.13 35.65 37.98 2.33 6.53
7 562.53 562.63 0.10 0.02 110.68 108.67 −2.01 −1.81 48.22 49.95 1.73 3.58 35.26 37.78 2.52 7.15
8 518.52 517.81 −0.71 −0.14 103.71 100.89 −2.82 −2.71 45.43 46.50 1.07 2.36 33.14 35.20 2.06 6.23
9 482.69 481.03 −1.66 −0.34 95.65 94.51 −1.14 −1.19 41.40 43.67 2.27 5.49 30.06 33.09 3.03 10.08
10 510.88 513.21 2.33 0.46 102.45 100.10 −2.35 −2.30 45.51 46.15 0.64 1.40 33.67 34.94 1.27 3.77
Mean(SD) −0.06 (0.44) −2.19 (0.46) 3.15 (1.57) 6.96 (2.58)
Correl (p) 0.998 (0.000) 0.997 (0.000) 0.972 (0.000) 0.941 (0.000)