Skip to main content
. 2015 Dec 14;30(5):451–456. doi: 10.1002/jcla.21878

Table 6.

Sample Testing in Patients With Potential Interfering Factors (n = 423)

Elecsys HCV II Elecsys HCV Intec Livzon
IR% (COI> = 5) 19 (4.49%) 19 (4.49%) 17 (4.02%) 14 (3.31%)
IR% (COI<5) 2 (0.47%) 3 (0.71%) 1 (0.24%) 3 (0.71%)
RR% (COI>1) 21 (4.96%) 22 (5.20%) 18 (4.25%) 17 (4.02%)
Confirmed positive 16 (3.78%) 16 (3.78%) 16 (3.78%) 15 (3.55%)
Confirmed Indeterminate 3 (0.71%) 4 (0.95%) 1 (0.24%) 2 (0.47%)
Number of false positives 2 (0.47%) 2 (0.47%) 1 (0.24%) 0
Number of false negative 0 0 1 (0.24%) 1 (0.24%)
Specificity 99.52% (98.86%, 100.18%) 99.52% (98.86%, 100.18%) 99.76% (99.29%, 100.22%) 100%
Sensitivity 100% 100% 99.76% (99.29%, 100.22%) 99.76% (99.29%, 100.22%)
False results caused by interfering factors (RR/confirmed positive)
TP(+) (n = 25) 1/0 0/0 0/0 0/0
RF(+) (n = 20) 1/1 1/1 0/1 0/1
Dialysis (n = 100) 7/6 8/6 6/6 6/6
HIV (n = 50) 3/3 3/3 4/3 3/3