Skip to main content
. 2019 Oct 25;9:15345. doi: 10.1038/s41598-019-51872-9

Table 2.

Echocardiographic parameters of C57BL/6J and db/db mice.

6 weeks old 20 weeks old
C57BL/6J db/db C57BL/6J db/db
Anterior wall at end diastole, mm 0.80 ± 0.02 0.96 ± 0.03* 0.90 ± 0.04* 1.14 ± 0.03*†#
Anterior wall at end systole, mm 1.31 ± 0.04 1.54 ± 0.05* 1.26 ± 0.05 1.63 ± 0.05*#
Posterior wall at end diastole, mm 0.80 ± 0.03 0.91 ± 0.04* 0.88 ± 0.03 1.16 ± 0.05*†#
Posterior wall at end systole, mm 1.18 ± 0.05 1.32 ± 0.04* 1.19 ± 0.05 1.46 ± 0.06*#
LV internal diameter at end diastole, cm 3.80 ± 0.08 3.71 ± 0.13 4.17 ± 0.09*† 3.78 ± 0.16
LV internal diameter at end systole, mm 2.25 ± 0.12 2.08 ± 0.14 2.88 ± 0.11*† 2.58 ± 0.11
Fractional shortening, % 41 ± 3 45 ± 3 31 ± 1*† 31 ± 2*†
Peak E wave velocity, mm/s 682 ± 24 746 ± 29 573 ± 15*† 592 ± 28*†
Peak A wave velocity, mm/s 438 ± 22 499 ± 15* 351 ± 21*† 601 ± 38*†#
Peak E/A ratio 1.59 ± 0.09 1.50 ± 0.06 1.68 ± 0.08 1.00 ± 0.03*†#

LV = left ventricle; ms = millisecond. *P < 0.05 versus 6 week-old C57BL/6J mice; P < 0.05 versus 6 week-old db/db mice; and #P < 0.05 versus 20 week-old C57BL/6J mice (n = 12–13 mice/group).