Skip to main content
. 2019 Jul 16;4(4):668–673. doi: 10.1016/j.adro.2019.07.007

Table 1.

Planning dose constraints for FASTR-2 and FASTR

Volume Dose constraint
FASTR-2 FASTR9
PTV prostate and seminal vesicle D95 = 35 Gy D95 = 40 Gy
D5 = 33 Gy D5 = 42 Gy
Dmax = 38 Gy Dmax = 43 Gy
PTV nodes D95 = 25 Gy
D5 = 28 Gy
Dmax = 41 Gy (within 1 cm of high dose volume)
Dmax = 28 Gy (outside 1 cm of high dose volume)
Bladder V26 ≤ 50% V29 ≤ 50%
V31 ≤ 30% V35 ≤ 30%
Rectum V20 ≤ 60% V27 ≤ 50%
V24 ≤ 50% V35 ≤ 20%
V32 ≤ 10%
V35 ≤ 2 mL
Small bowel V27.5 ≤ 2 mL V27.5 ≤ 2 mL
V25 ≤ 190 mL V25 ≤ 190 mL