Skip to main content
. 2019 May 2;53(5):334–339. doi: 10.1016/j.aott.2019.04.001

Table 3.

Visual analog scale pain scores of patients according to adductor block technique.

Postoperative time (h) Visual analog scale score
F value p Value 95% CI of difference
SACB (n = 60) CACB (n = 63) Lower Upper
At rest
 1 3.93 ± 3.73 1.13 ± 1.83 38.107 <0.001 1.763 3.850
 2 5.68 ± 3.53 2.84 ± 2.61 10.854 <0.001 1.735 3.949
 3 7.23 ± 2.67 4 ± 2.62 0.031 <0.001 2.288 4.179
 4 7.07 ± 2.49 3.63 ± 2.07 1.393 <0.001 2.614 4.249
 5 7.08 ± 2.36 3.73 ± 1.78 3.944 <0.001 2.608 4.098
 6 6.78 ± 2.3 3.7 ± 1.91 2.638 <0.001 2.332 3.838
 7 6.4 ± 2.47 3.59 ± 2.16 1.033 <0.001 1.983 3.643
 8 6.3 ± 2.51 3.46 ± 2.32 0.548 <0.001 1.977 3.702
 9 6.2 ± 2.41 3.13 ± 2.15 2.446 <0.001 2.258 3.888
 10 6.03 ± 2.65 3.17 ± 2.31 3.419 <0.001 1.973 3.745
 11 5.8 ± 2.74 3.06 ± 2.21 6.57 <0.001 1.848 3.625
 12 4.95 ± 2.7 2.71 ± 2.09 4.023 <0.001 1.374 3.097
 24 3.9 ± 1.67 2.56 ± 2.05 2.136 <0.001 0.674 2.015
 36 2.82 ± 1.37 1.84 ± 1.71 1.932 0.001 0.421 1.53
 48 2.32 ± 1.15 1.4 ± 1.23 1.892 <0.001 0.492 1.348
 60 1.97 ± 1.02 1.16 ± 1.15 4.357 <0.001 0.418 1.198
 72 1.83 ± 0.99 1.14 ± 1.06 2.268 <0.001 0.323 1.058
After mobilization
 24 4.75 ± 1.55 3.3 ± 1.84 1.74 <0.001 0.837 2.06
 48 3.13 ± 1.15 2.21 ± 1.2 1.996 <0.001 0.0505 1.349

Variables are mean ± standard deviation (SD) or number.