Skip to main content
. 2019 Oct 29;7:283. doi: 10.3389/fbioe.2019.00283

Table 1.

Evaluation of parameters by multiple polynomial regression—parameterization with sigma limitations—concentration of CO in sterile and non-sterile material.

Type of waste treatment Effect COs, ppmv (Param.) COs, ppmv (Standard deviation) COs, ppmv(t) COs, ppmv (p) -95.00% confidence interval +95.00% confidence interval COs, ppm v/v[Beta (β)] COs, ppm v/v (Standard deviation β) −95.00% confidence interval +95.00% confidence interval
Sterile Intercept 884.598 416.518 2.124 0.035 64.575 1704.622
T,°C −1.921 0.708 −2.712 0.007 −3.316 −0.527 −0.410 0.151 −0.708 −0.112
T,°C2 0.066 0.008 8.125 0.000 0.050 0.082 1.185 0.146 0.898 1.473
t, h 0.237 0.235 1.009 0.314 −0.225 0.699 0.134 0.133 −0.128 0.396
t, h2 −0.002 0.001 −1.443 0.150 −0.004 0.001 −0.192 0.133 −0.453 0.070
O2s, % v/v −111.268 81.797 −1.360 0.175 −272.307 49.771 −4.083 3.002 −9.993 1.826
O2s, % v/v2 3.337 2.979 1.120 0.264 −2.527 9.201 3.574 3.190 −2.706 9.854
CO2s, % v/v 40.432 46.543 0.869 0.386 −51.201 132.064 1.365 1.571 −1.728 4.458
CO2s, % v/v2 −4.464 3.419 −1.306 0.193 −11.196 2.268 −1.991 1.525 −4.994 1.012
Non-sterile Intercept 504.635 132.936 3.796 0.000 243.031 766.240
T,°C −8.321 2.025 −4.110 0.000 −12.306 −4.337 −1.466 0.357 −2.168 −0.764
T,°C2 0.153 0.026 5.940 0.000 0.102 0.204 2.255 0.380 1.508 3.002
t, h −0.910 0.387 −2.352 0.019 −1.670 −0.149 −0.430 0.183 −0.789 −0.070
t, h2 0.002 0.002 1.202 0.230 −0.002 0.007 0.216 0.180 −0.138 0.569
O2ns, % v/v −6.113 15.417 −0.396 0.692 −36.451 24.226 −0.339 0.854 −2.019 1.342
O2ns, % v/v2 −0.765 0.659 −1.160 0.247 −2.062 0.533 −0.915 0.789 −2.468 0.637
CO2ns, % v/v −18.152 15.826 −1.147 0.252 −49.297 12.993 −0.935 0.815 −2.540 0.669
CO2ns, % v/v2 0.121 0.765 0.159 0.874 −1.383 1.626 0.126 0.790 −1.429 1.680