Skip to main content
. 2019 Nov 5;6(6):ENEURO.0306-19.2019. doi: 10.1523/ENEURO.0306-19.2019

Table 6.

Characteristics of slow oscillations during overnight closed-loop stimulation (experiment 2).

Stim Sham p Value
Number of SOs (stimulation period) 529.37 (74.71) 477.05 (60.75) 0.59
Number of SOs (entire night) 1356.37 (111.47) 1338.89 (106.62) 0.87
SO amplitude (μV) 141.93 (9.16) 128.62 (10.06) 0.24
SO slope (μV/s) 277.64 (21.97) 244.02 (20.80) 0.14
Duration (s) 1.18 (0.01) 1.14 (0.07) 0.49

Mean ± SEM number of slow oscillations (SOs identified off-line; see Materials and Methods) during SWS epochs of the stimulation period and the entire night, amplitude (negative half-wave to positive-peak), slope, and duration between stim and sham conditions.