Comparison of different GC-sensor systems with developed FBAR sensor in terms of limit of detection, dynamic range, linearity, application field and data process method, adapted with permission from [184].

GC-Sensor Sensing Performance Application Field Data Process Method Ref.
Limit of Detection Dynamic Range Linearity
Micro-cantilever Sub-ppb / Good Building-related illness PCA [185]
Semiconductor metal oxide detector Sub-ppb 0.1–5 ppb Non-linearity Environmental pollution / [186]
Micro-capacitive detector 0.1 ppm 0.1–1 ppm Good Indoor pollutants / [187]
Acoustic wave (AW) device / / Good Food products and antiseptic agent PCA [188]
Nano-electromechanical resonators Sub-ppb 0.6–1500 ppb Good / / [189]
Film bulk acoustic wave resonator 1 ppm 50–500 ppm Good Exhaled breath detection PCA This work