Table 4.

Multivariate analysis for risk factors of the false negative rate in sentinel lymph node biopsy.

Variables Odds ratio 95% CI P
Number of metastatic lymph nodes 2.801 1.159–6.771 0.022
Number of dissected SLNs 0.461 0.269–0.790 0.005
Tumor size 0.223 0.047–1.050 0.058