Skip to main content
. 2019 Sep 27;11(10):1575. doi: 10.3390/polym11101575

Table 1.

Limiting oxygen index (LOI), vertical burning rate (UL-94) testing results and combustion parameters of the prepared samples.

Sample LOI (%) UL-94 Time to Ignition (s) Time to Flameout (s) THR
(MJ/m2)
PHRR
(kW/m2)
TSR
(m2/m2)
Residue
(%)
ZnAlg 49 V-0 22 387 29.71 162.31 274.28 51.29
ZnAlg/Cu2O 58 V-0 37 610 25.71 83.18 288.75 56.74