Skip to main content
. 2019 Oct 16;8(10):503. doi: 10.3390/foods8100503

Table 2.

Summary of recent studies combining MAE (MAS) with DLLME for determining hydrocarbon contaminants in food.

Compounds
and Food
MAE Conditions Pre-Treatment before DLLME Extractant/Disperser Analysis Enrichment Factors Recovery (%) LODng/g (or mL) Reference
EPA PAH
 
Smoked fish
1 g sample + 12 mL KOH (2 M)/ethanol (50:50) pH 6.5 Ethylene tetrachloride (100 μL)/Acetone (500 uL) GC-MS 244–373 82–106 0.11–0.43 [46]
EPA PAH
 
Smoked fish
1 g sample + 10 mL KOH (2 M)/ethanol (50:50); microw. at 500 MHz for 2 min. pH 5 + Carrez Ethylene tetrachloride (150 μL)/Acetone (500 uL) GC-MS [47]
EPA PAH
 
Grilled meat
1 g sample + 10 mL of KOH (2 M)/ethanol (50:50); microwaved at 500 MHz for 1.5 min pH 6 + Carrez Ethylene tetrachloride (80 μL)/Acetone (300 μL) GC-MS 110–265 85–104 0.15–0.3 [48]
PAH
 
4Smoked rice
1 g of sample + 10 mL of KOH (2 M)/ethanol 1:1); microwaved at 500 MHz for 1.5 min pH 5 + Carrez Chloroform (250 μL)/Acetonitrile (1.2 mL) HPLC-UV 258–307 87–98 0.05–0.12 [49]
EPA PAH
 
Bread
1 g of sample + 10 mL of KOH (1 M)/ethanol (60:40); microwaved at 500 MHz for 1.5 min pH 6.5 + Carrez Ethylene tetrachloride (80 μL)/Acetone (300 μL) GC-MS 200–300 85–104 0.1–0.3 [50]
PAH4
 
Toasted bread
2 g of sample + 10 mL of KOH (1 M)/ethanol (50:50); microwaved at 500 MHz for 1.5 min pH 6 + Carrez Chloroform (180 μL)/Acetonitrile (0.9 mL) HPLC 255–312 87–104 0.03–0.19 [51]
Heavy PAH
 
Coffee
0.5 g sample + 0.5 mLwater + 10 mL KOH (85% v/v) in ethanol; microw. at 520 MHz for 8 min pH 6 + Carrez Ethylene tetrachloride (80 μL)/Acetone (300 μL) GC-MS 155–248 88–101 0.1–0.3 [52]
PAH
 
vegetables
10 mL homogenate sample + 4 mL acetone; microw. at 400 W for 1.5 min 1-bromo-3-methylbutane (30 µL)/Acetone (800 µL) GC-FID [53]
PAH
 
Edible oils
Sample + acetonitrile/acetone (1:1) and methanolic KOH (in two steps). Ethylene tetrachloride/Ethanol GC-MS 81–124 0.2–2.7 [54]

Abbreviations: DLLME: dispersive liquid-liquid micro-extraction; UV: ultraviolet.