Table 5. Marginal bone loss (MBL) evaluation on the mesial and distal aspects of short dental implants at 3 months, 1 year, and 2 years.
MBL from installation (mm)1 | MBL from previous visit (mm)2 | |||
---|---|---|---|---|
Mesial | Distal | Mesial | Distal | |
3 months | 0.34±0.47 | 0.53±0.57 | 0.34±0.47 | 0.53±0.57 |
1 year | 0.53±0.58 | 0.67±0.56 | 0.19±0.24 | 0.14±0.02 |
2 years | 0.58±0.60 | 0.71±0.60 | 0.05±0.12 | 0.04±0.05 |
1Mean MBL at 3 months, 1 year, and 2 years was significantly higher than at implant installation (P<0.05).
2Mean MBL at 1 year was significantly higher than at 3 months. MBL at 1 and 2 years did not differ significantly (P<0.05).