Skip to main content
. 2019 Nov 5;13:1116. doi: 10.3389/fnins.2019.01116

TABLE 3.

Analysis of other HRV parameters.

Heart rate variability (HRV) Overall: n = 16 Time course Unifactoriell GLM – Post hoc
parameters (24 h mean) (time points; 24 h mean) time effect test (LSD)




Pre- Peri- Rehabilitation Long-term
Mean ± SD Unit operative (1) operative (2) (3) recovery (4) F P ηp2 p < 05
vagal activity (logRSArr) 0,94 ± 0,17 log(ms) 0,98 0,88 0,93 0,97 3,24 0.046 0,18 1 vs. 2; 2 vs. 4
Consecutive inter-beat intervals (RR) 788,67 ± 75,33 ms 790,49 760,15 794,48 809,56 4,16 0.011 0,22 2 vs. 3, 4
Heart rate (HR) 78,69 ± 7,81 bpm 78,91 80,60 78,34 76,90 2,49 0.072(*) 0,14 2 vs. 4
Standard deviation of RR (SDNN) 45,65 ± 9,37 ms 49,49 40,22 46,26 46,61 5,00 0.016 0,25 1 vs. 2
Total variability pow er (InTOTrr) 7,11 ± 0,45 ln(ms2) 7,30 6,90 7,10 7,14 3,95 0.035 0,21 1 vs. 2, 3
Low frequency power (InLFrr) 5,57 ± 0,51 ln(ms2) 5,76 5,31 5,58 5,63 4,65 0.019 0,24 1 vs. 2; 2 vs. 4
High frequency pow er (InHFrr) 4,37 ± 0,91 ms2 4,53 4,12 4,37 4,47 2,70 0.077(*) 0,15 1 vs. 2
Very low frequency power (InVLFrr) 6,46 ± 0,40 ms2 6,64 6,29 6,43 6,45 3,18 0.065(*) 0,17 1 vs. 2, 3
Ratio LF/HF 1,20 ± 0,60 [ ] 1,23 1,18 1,21 1,16 0,19 0.830 0,01
Respiratory rate (ATMFrsa) 17,52 ± 1,29 fpm 17,02 17,64 17,46 17,95 3,19 0.062(*) 0,18 1 vs. 3,4; 3 vs. 4

Marked levels of significance: (*)p < 0.1 and p < 0.05.