Table 4.
Complications related to neck-shaft-angle
Reduction quality | Total | < 125° | 125°–129° | 130°–134° | ≥ 135° |
---|---|---|---|---|---|
No secondary surgery | 145 (75.1%) | 24 (16.6%) | 63 (43.4%) | 44 (30.3%) | 13 (9.0%) |
Secondary surgery | 48 (24.9%) | 12 (25.0%) | 17 (34.7%) | 17 (34.7%) | 1 (2.1%) |
Fixation failure | 8 | 4 (50.0%) | 3 (37.5%) | 0 (0.0%) | 1 (12.5%) |
Nonunion | 12 | 1 (8.3%) | 3 (25.0%) | 7 (58.3%) | 0 (0.0%) |
Infection/hematoma | 2 | 0 (0.0%) | 1 (50.0%) | 1 (50.0%) | 0 (0.0%) |
Painful hardware | 17 | 4 (23.5%) | 7 (41.2%) | 6 (35.3%) | 0 (0.0%) |
AVN of the femoral head | 2 | 1 (50.0%) | 1 (50.0%) | 0 (0.0%) | 0 (0.0%) |
Malunion | 6 | 2 (33.3%) | 2 (33.3%) | 2 (33.3%) | 0 (0.0%) |
Heterotopic ossifications | 1 | 0 (0.0%) | 0 (0.0%) | 1 (100.0%) | 0 (0.0%) |