Skip to main content
. Author manuscript; available in PMC: 2019 Nov 14.
Published in final edited form as: Diagn Microbiol Infect Dis. 2011 Feb;69(2):145–152. doi: 10.1016/j.diagmicrobio.2010.10.021

Table 3.

Results of real-time PCR and DFME on respiratory samples from patients evaluated for pulmonary infection, including PCP, from January 2005 through May 2007a

Description Number of tests
Testing performed from all respiratory sourcesb 3271
 DFME only: 2145 total
  Negative 2101 (98%)
  Positive 44 (2%)
 Real-time PCR only: 734 total
  Negative 633 (86%)
  Positive 101 (14%)
 Both tests done on same samplec: 392 total
  DFME negative, PCR negative 363 (93%)
  DFME negative, PCR positive 29 (7%)
Testing performed from BAL fluid only 1422
 DFME only: 934 total
  Negative 910 (97%)
  Positive 24 (3%)
 Real-time PCR only: 156 total
  Negative 140 (90%)
  Positive 16 (10%)
 Both tests done on same samplec: 332 total
  DFME negative, PCR negative 311 (94%)
  DFME negative, PCR positive 21 (6%)
a

Patient samples collected from both Mayo Clinic Rochester and Mayo Medical Laboratories.

b

Respiratory sources include sputum, tracheal secretions, BAL, and bronchial washings.

c

These samples all tested negative by DFME and subsequently had PCR added.