Skip to main content
. 2019 Nov 8;13:66. doi: 10.3389/fnsys.2019.00066

Table 1.

The average of peak LDA classification accuracies for the right and left finger movement vs. resting state of all the participants using LRTC, ARFIMA, ERD, hybrid LRTC+ERD and hybrid ARFIMA+ERD features.

Left finger tapping Right finger tapping
Accuracy Sensitivity Specificity Accuracy Sensitivity Specificity
(%) (%) (%) (%) (%) (%)
LRTC Mean 75.69 75.85 75.53 76.07 76.39 75.75
SD 6.77 9.10 6.32 6.40 6.05 7.92
ARFIMA Mean 88.05 87.35 88.75 86.54 86.92 86.15
SD 4.75 5.51 4.53 4.98 5.20 5.77
ERD Mean 72.98 83.00 62.95 71.04 79.78 62.30*
SD 5.23 12.12 10.08 6.40 14.30 9.00
LRTC Mean 77.82 78.50 77.13 78.62 78.37 78.86
+ ERD SD 6.97 9.66 7.17 7.14 8.11 7.94
ARFIMA Mean 89.04 89.29 88.79 87.58 87.56 87.60
+ ERD SD 3.74 4.57 4.35 4.56 5.40 4.64

All values except the ones marked by

*

are significantly above chance level (p <0.05).