Performance of three models

Model C-index 95% CI P AIC
95% CI, 95% confidence interval; AIC, Akaike information criterion; *, C-indexes of texture signature and clinical nomogram were compared; **, C-indexes of clinical nomogram and combined nomogram were compared; ***, C-indexes of texture signature and combined nomogram were compared.
Texture signature 0.878 0.791−0.937 0.200* 85.52
Clinical nomogram 0.795 0.696−0.873 0.001** 110.00
Combined nomogram 0.936 0.863−0.977 0.030*** 73.65