Key features of acquisition protocol of two subtypes of dynamic contrast-enhanced CT

Dynamic multiphase CT Dynamic ‘ first pass’/perfusion CT
Area of coverage 6 cm 7-10 cm depending on tumour
Slice thickness 3 mm 5 mm
kVp 100 kVp 80 kVp
mAs According to patient’s weight: <60 Kg, 200 mAs 60-90 Kg, 350 mAs >90kg. 500 mAs 80 mAs
Rate of contrast 2ml/sec 5 ml/sec
Time delay/phase of acquisition Pre-contrast, 60 sec, 120 sec, 180 sec and 240 sec. Scan delay: 5 sec, 22 dynamic acquisitions: first 10 scans every 3 sec, next 5 scans every 2 sec and next 7 scans every 4 sec
Reconstruction Reconstruction interval: 2mm Standard mediastinal window: (windowlevel: 40HU, width: 400HU) Reconstruction interval: 3 mm Standard mediastinal window: (windowlevel: 40HU, width: 400HU)
Parameter available Peak enhancement (HU), Wash in and wash out percentages Blood flow, blood volume, permeability, mean transit time, time to peak