Skip to main content
. 2019 Nov 18;12:272. doi: 10.1186/s13068-019-1614-5

Table 1.

Independent variables of the central composite design and results of response surface analysis [xylooligosaccharide (XOS) yields]

Variables Responses
Reaction temperature (°C) Reaction time (min) XA concentration (mol/L) XOS yields (%)
130 15 0.25 1.03
130 15 1 1.31
130 75 0.25 16.99
130 75 1 11.68
150 45 0.625 42.61
150 45 0 0.88
150 45 1 32.50
150 95 0.625 40.18
170 15 0.25 15.95
170 15 1 31.22
170 75 0.25 18.96
170 75 1 8.75
183 45 0.625 17.97