Skip to main content
. 2019 Nov 1;12(21):3599. doi: 10.3390/ma12213599

Table 4.

Mechanical and electrical properties of tested elastic textile/polymer composite-based stretchable circuit boards.

Property Unit Woven Textile Knitted Textile Nonwoven Textile
max. force Fmax [N] 21–22.5 19–21 11–13
strain at break A [%] 31–40 65–74 70–75
initial resistance R0 [Ω] 4.8–6.4 2.4–2.8 7.8–20.1
initial sheet resistance R0, square [mΩ/□] 120–160 60–70 195–502.5
resistance at break Rbreak [Ω] 11.5–16.4 7.4–8.9 61–100
max. resistance change
ΔRmax=RbreakR0
[-] 2.5–3.5 2.6–3.7 5–8