Skip to main content
. 2019 Oct 24;12(21):3484. doi: 10.3390/ma12213484

Table 6.

The compressive strength of insulation materials after applying by CFRP.

Specimen CFRP, No. of Layer Compressive Strength (MPa) Average compressive Strength (MPa) Increase Percentage (%)
P08 0 9.44 8.99 -
8.73
8.80
P08C1 1 31.43 32.16 258
32.68
32.37
P08C2 2 53.01 52.18 480
51.83
51.69
P15 0 4.92 4.88 -
4.70
5.02
P15C1 1 22.30 21.85 348
21.11
22.15
P15C2 2 38.25 39.39 707
40.37
39.56
P20 0 3.47 3.36 -
3.16
3.55
P20C1 1 19.63 19.22 472
18.94
19.09
P20C2 2 34.76 35.72 963
36.44
35.95
P25 0 1.83 1.76 -
1.75
1.71
P25C1 1 18.34 18.08 927
17.25
18.64
P25C2 2 30.16 28.89 1541
28.83
27.67