Skip to main content
. 2019 Oct 25;12(21):3499. doi: 10.3390/ma12213499

Table 1.

The accuracy (trueness and precision) of four groups for full arch.

Group Root Mean Square (RMS) (µm)
Trueness Precision
Mean ± SD 95% CI Mean ± SD 95% CI
CON 27.9 ± 2.7a 26.0–29.8 20.0 ± 3.1a 19.1–21.0
MIL 94.0 ± 11.5b 85.8–102.3 37.8 ± 7.0b 35.7–39.9
S3P 85.2 ± 13.1b 75.9–94.6 49.6 ± 12.1c 45.9–53.2
D3P 105.5 ± 22.5b 89.4–121.6 52.8 ± 17.5c 47.6–58.1
p <0.001 <0.001

Values followed by the same letter were not significantly different (p > 0.05/6 = 0.008). p-values are from a Kruskal–Wallis test. RMS, root mean square; SD, standard deviation; CI, confidence interval; CON, conventional gypsum model; MIL, milled gypsum model; S3P, SLA 3D printed photopolymer model; D3P, DLP 3D printed photopolymer model.