Skip to main content
. 2019 Nov 3;19(21):4781. doi: 10.3390/s19214781

Table 2.

Comparison of electrochemical methods.

Electrochemical Methods
Target
Analyte
Detection
Principle
Sensing
Element
Sensing
Material
Substrate LOD Real Sample Ref.
Hg+2 ASV Electrode system WE: Au PDMS 3 ppb No [101]
CE: Au
RE: Ag
Pb+2
and Hg+2
CV Electrode system WE: carbon Polyethylene
terephthalate
50 μM each No [104]
CE: Ag
RE: Ag/Cl
Pb+2 SWASV Electrode system WE: Ag Polymer 0.55 ppb No [99]
CE/QRE: Ag
Pb+2
and Hg+2
SWASV Electrode system WE: carbon Paper 2.0 and 2.3 ppb,
resp.
water
Soda water and
dirty ground
[111]
CE: carbon
RE: Ag pseudo
As CV Electrode system WE: Ag Plastic 1 ppb No [102]
CE: Carbon
RE: Ag/AgCl
As SWASV Electrode system WE: Au/SWCNT PDMS 4.5 ppb No [103]
CE and RE: SWCNT
As(III) Amperometry Bioreporter with
electrode system
WE: Au Plastic 0.8 ppb Tap and ground
water
[112]
CE and RE: Ag
and E. coli
Nitrate CV Electrode system WE and RE: Ag Glass 25 ppb [113]
CE: Au
Nitrate CV Electrode system WE: Ag Glass 0.2 ppm Field and
environmental
water
[114]
CE: Au
RE: Ag
Nitrate and
Potassium
Potentiometric Electrode system WE: Polymeric membrane Green tapes 9.56 and 0.81 mg/L,
respectively
Water from
recycling unit
[115]
RE: Ag/AgCl
Nitrate Potentiometric Electrode system with modified working electrode WE: f-MWCNTs
RE:Ag/AgCl
Lipophilic carbon nanotubes 5×10−7 M Desalinated seawater [116]
Nitrate EIS Electrode system with modified working electrode WE: NiR/nTiO2-GF
CE: Au
RE: Ag/AgCl
PDMS 1 μM No [117]
Nitrate and
Nitrite
SWV Electrode system with modified working electrode WE: Cu/MWCNT/RGO/GCE
CE: Pt-wire
RE: Ag/AgCl
GCE 20 and 30 nM, resp. Tap and mineral water [77]
E. coli Voltammetry Electrode system with modified working electrode WE: immobilized DNA
probe on Au
CE and RE: Pt
Glass 100 nM No [118]
Hepatitis B ASV Electrode system WE: GCE
CE: Pt wire
RE: Ag/AgCl and
DNA modified AgNP
Paper 85 pM No [119]
E. coli Amperometry Immunoassays Antibody PMMA 50 CFU/mL Real sample [120]
E.coli Positive
dielectrophoresis
Sensing and focusing electrode Not specified PDMS 300 CFU/mL No [121]
E. coli EIS Interdigitated electrodes Modified silicon
sensor chip
Silicon
and PDMS
10 cells/mL No [122]
E. coli and
S. aureus
EIS Coplanar electrode Au electrode Silicon 522 cells/mL No [123]
E. coli and
Enterococci
Coulter
principle
Microfluidic sensing
chip
Resistance detection
circuit
PDMS Individual cell Ballast water
sample
[124]
Salmonella
typhimurium
Impedance analyzer Interdigitated
electrodes
Au electrode with
immobilized antibodies
PDMS 3×103 CFU/mL No [125]

LOD: Limit of detection; ASV: Anodic stripping voltammetry; PDMS: Polydimethylsiloxane; PMMA: Poly(methyl methacrylate); CV: Cyclic voltammetry; SWASV: Square-wave anodic stripping voltammetry; QRE: Quasi-reference electrode; WE:Working electrode; CE: Counter electrode; RE: Reference electrode; EIS: Electrochemical impedance spectroscopy; SWV: Square-wave voltammetry; RGO: Reduced graphene oxide; GCE: Glassy carbon electrode; -MWCNTs: Functionalised- multiwall carbon nanotube.