Published in final edited form as: Osteoarthritis Cartilage. 2009 Feb 9;17(7):856–863. doi: 10.1016/j.joca.2009.01.007

Table V.

Proposed cut-off values of radiological JSW in millimeters based on the measurement error (e.g., Bland and Altman method with SDD in knee OA)

Author Year Analysis* Film Bland and Altman method
N Mean change SD change SDD mm (cut-off) Limits of agreement
Min Max
Ravaud 1996 3 (52) 1 55 −0.01 0.43 0.84 −0.85 0.83
1 1 55 0.2 0.33 0.64 −0.44 0.84
Ravaud 1998 2 1 36 −0.03 0.32 0.62 −0.65 0.59
Mazzucca 2002 2 1 76 0 0.3 0.6 −0.6 0.6
Buckland-Wright 2003 2 1 266 −0.012 0.169 0.33 −0.342 0.318
Vignon 2003 1 2 36 0 0.25 0.5 −0.5 0.5
Conrozier 2004 1 1 (semi-auto) 127 0.01 0.14 0.27 −0.26 0.28
1 1 (auto) 127 0.005 0.06 0.12 −0.115 0.125
Lavalley 2005 2 3 355 −0.01 0.43 0.84 −0.85 0.83
*

Analysis: 1 = score of a single film in a single patient; 2 = score of two films in a single patient taken less than 2 days a part; 3 = score of the changes in a single patient between two visits and if yes precise () the number of weeks between these two visits.

Film: 1 = antero-posterior view; 2 = flexed view; 3 = lateral view.