Table I.

Main hardware characteristics, acquisition parameters of structural MRI sequences, and averagesignal‐to‐noise ratio (SNR) from the left primary sensorimotor cortex (SMC) in the different centers participating into the study

Scanner Coil Dual/T2‐weighted sequence FLAIR sequence 3D T1‐weighted sequence Average SNR (SD)
Center 1 Siemens Sonata Circular polarized head coil TR = 2800 TE = 94 slices = 19 thickness = 3 FOV = 250 matrix = (205)2 TR = 9000 TE = 105 TI = 2200 slices = 17 thickness = 5 FOV = 250 TR = 2700 TE = 4 slices = 160thickness = 1.5 FOV = 260orientation = axial 190.3 (22.3)
Center 2 Siemens Symphony Maestro Class Quadrature whole head coil TR = 3500 TE = 14/86slices = 23 thickness = 5 FOV = 256 matrix = (256)2 TR = 9000 TE = 114 TI = 2500 slices = 23 thickness = 5 FOV = 250 TR = 2050 TE = 3.93 slices = 144 thickness = 1 FOV = 256 orientation = sagittal 230.8 (14.5)
Center 3 Siemens Sonata Circular polarized head coil TR = 3230 TE = 84 slices = 21 thickness = 5 FOV = 240 matrix = (512)2 TR = 9000 TE = 108 TI=2400 slices = 21 thickness = 5 FOV = 240 TR = 1800 TE = 4.38 slices = 144 thickness = 1 FOV = 240 orientation = axial 301.5 (20.6)
Center 4 Philips Intera Circular polarized head coil TR = 2300 TE = 80 slices = 24 thickness = 5.5 FOV = 230 Matrix = (256)2 TR = 8000 TE = 110 TI = 2100 slices = 24 thickness = 5 FOV = 230 mm TR = 20 TE = 4 slices = 126 thickness = 1FOV = 256 orientation = axial 356.5 (18.2)
Center 5 GE Signa Excite 11.0 Birdcage head coil TR = 5900 TE = 102 slices = 22 thickness = 5 FOV = 240 matrix = (512)2 TR = 9895 TE = 140 TI = 2473 slices = 22 thickness = 5 FOV = 240 matrix = (256)2 TR = 20 TE = 2.3 slices = 146thickness = 1.5 FOV = 260 orientation = coronal 300.8 (19.3)
Center 6 Siemens Vision Quadrature whole head coil TR = 3300 TE = 16/98 slices = 24 thickness = 5 FOV = 250 matrix = (256)2 NA TR = 11.4 TE = 4.4 slices = 160 thickness = 1 FOV = 250 orientation = sagittal 79.1 (9.4)
Center 7 Siemens Sonata Circular polarized head coil TR = 5000 TE = 90 slices = 25thickness = 6 FOV = 250 matrix = (256)2 TR = 10000 TE = 139 TI = 2400 slices = 25 thickness = 6 FOV = 250 NA 337.8 (24.3)
Center 8 Philips Gyroscan ACS‐NT15 Standard head coil TR = 2074 TE = 34 slices = 50 thickness = 3 FOV = 250 matrix = (256)2 TR = 9000 TE = 150 TI = 2725 slices = 50 thickness = 3 FOV = 250 TR = 20 TE = 3 slices = 50 thickness = 3 FOV = 250 orientation = axial 267.5 (10.2)

TR, TE, and TI are expressed in ms, slice thickness and FOV are expressed in mm, SNR is a dimensionless index.

TR, repetition time; TE, echo time; TI, inversion time; FOV, field of view; SNR, signal‐to‐noise ratio; NA, not acquired.