Skip to main content
. 2007 Mar 29;29(3):265–280. doi: 10.1002/hbm.20386

Table III.

Simulated‐dipole parameters and ECD results for source estimation: Simulation 1

Simulated‐dipole parameters ECD results; SNR = 21.8 dB
Index Location Moment Location Moment Distancea (mm) Gof (%)
SM1‐dipole x −35.2 0.42 −35.3 0.43
y −7.2 0.80 −7.2 0.79 1.03 97.2b
z 88.9 0.41 88.3 0.41
a

Between the simulated and the estimated location.

b

85% Gof.