Skip to main content
. 2016 Dec 30;3(2):277–284. doi: 10.14338/IJPT-16-00010.1

Table 4.

Dosimetric values for the lungs and esophagus; proton doses are given in Gy (IsoE).

Patient no.
Both lungs, Mean dose (Gy)
Right lung, Mean dose (Gy)
Esophagus, Mean dose (Gy)
Photon
Proton
Photon
Proton
Photon
Proton
 1 2.2 1.2 3.3 2.2 7.0 1.7
 2 0.5 0.0 0.6 0.0 1.8 0.0
 3 9.6 5.5 11.9 8.9 16.3 0.6
 4 2.2 0.7 3.3 0.7 5.4 0.0
 5 1.1 0.2 1.1 0.4 7.1 0.2
 6 5.3 3.6 8.1 6.7 7.1 0.5
 7 0.1 0.0 0.2 0.0 0.3 0.0
 8 4.4 0.2 5.0 0.4 12.7 0.0
 9 0.6 0.0 0.6 0.0 0.4 0.0
10 2.3 0.5 3.2 0.9 2.2 0.8
Mean 2.8 1.2 3.7 2.1 6.0 0.4
P value .002 .002 .002